Objective: To determine the impact of a telemedicine system, the electronic intensive care unit (eICU), on ICU, and non-ICU mortality, total mortality, total and ICU-specific length of stay, and total hospital cost at two community hospitals.
Design: Observational study with one baseline period and two comparison periods (eICU wave one and eICU wave two). Each time period was 4 months in duration.
Setting: Four ICU from two community hospitals in the metropolitan Chicago area. Hospital one is a 610-bed teaching hospital with three adult ICU (ten-bed medical ICU, ten-bed cardiac ICU, and 14-bed surgical ICU). Hospital two is a 185-bed nonteaching hospital with a ten-bed mixed medical/surgical ICU.
Patients: All patients 18 yrs or older with an ICU stay of at least 4 hrs during the specified time period were included.
Interventions: The eICU was implemented at both hospitals in April 2003.
Measurements and Main Results: Mortality, length of stay, and total cost were measured. Age, gender, race/ethnicity, trauma status, Acute Physiology and Chronic Health Evaluation III score, and physician utilization of the eICU were included as covariates. Included in the analysis were 4088 patients (1371 at baseline, 1287 in eICU wave one, and 1430 in eICU wave two).
- The eICU did not have a significant effect on ICU/non-ICU/total mortality or hospital length of stay.
- ICU length of stay increased over time and was associated with higher physician utilization of the eICU.
- Although total hospital costs increased over time, the rate of increase was steeper for those patients whose physicians permitted only a low level of eICU involvement.
Clinical and economic outcomes of the electronic intensive care unit: Results from two community hospitals - Critical Care Medicine: January 2010 - Volume 38 - Issue 1 - pp 2-8